Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 14(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38667160

RESUMEN

Galactose monitoring in individuals allows the prevention of harsh health conditions related to hereditary metabolic diseases like galactosemia. Current methods of galactose detection need development to obtain cheaper, more reliable, and more specific sensors. Enzyme-containing amperometric sensors based on galactose oxidase activity are a promising approach, which can be enhanced by means of their inclusion in a redox polymer coating. This strategy simultaneously allows the immobilization of the biocatalyst to the electroactive surface and hosts the electron shuttling units. An additional deposition of capping polymers prevents external interferences like ascorbic or uric acid as well as biofouling when measuring in physiological fuels. This work studies the protection effect of poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate (MPC) and polyvinylimidazole-polysulfostyrene (P(VI-SS)) when incorporated in the biosensor design for the detection of galactose in human plasma.


Asunto(s)
Técnicas Biosensibles , Galactosa , Polímeros , Humanos , Polímeros/química , Galactosa Oxidasa , Metacrilatos/química
2.
ACS Sens ; 8(4): 1756-1765, 2023 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-36943936

RESUMEN

The lifetime of implantable electrochemical glucose monitoring devices is limited due to the foreign body response and detrimental effects from ascorbic acid (AA) and uric acid (UA) interferents that are components of physiological media. Polymer coatings can be used to shield biosensors from these interferences and prolong their functional lifetime. This work explored several approaches to protect redox polymer-based glucose biosensors against such interferences by designing six targeted multi-layer sensor architectures. Biological interferents, like cells and proteins, and UA and AA interferents were found to have individual effects on the current density and operational stability of glucose biosensors, requiring individual protection and treatment. Protection against biofouling can be achieved using a poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate) (MPC) zwitterionic polymer coating. An enzyme-scavenging approach was compared to electrostatic repulsion by negatively charged polymers for protection against AA and UA interferences. A multi-layer novel polymer design (PD) system consisting of a cross-linkable negatively charged polyvinylimidazole-polysulfostyrene co-polymer inner layer and a cross-linkable MPC zwitterionic polymer outer layer showed the best protection against AA, UA, and biological interferences. The sensor protected using the novel PD shield displayed the lowest mean absolute relative difference between the glucose reading without the interferent and the reading value with the interferent present and also displayed the lowest variability in sensor readings in complex media. For sensor measurements in artificial plasma, the novel PD extends the linear range (R2 = 0.99) of the sensor from 0-10 mM for the control to 0-20 mM, shows a smaller decrease in sensitivity, and retains high current densities. The application of PD multi-target coating improves sensor performance in complex media and shows promise for use in sensors operating in real conditions.


Asunto(s)
Incrustaciones Biológicas , Técnicas Biosensibles , Glucosa , Glucemia , Polímeros , Ácido Úrico/análisis , Automonitorización de la Glucosa Sanguínea , Ácido Ascórbico , Incrustaciones Biológicas/prevención & control
3.
Biosens Bioelectron ; 219: 114815, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36302333

RESUMEN

Foreign body response (FBR) is a major challenge that affects implantable biosensors and medical devices, including glucose biosensors, leading to a deterioration in device response over time. Polymer shields are often used to mitigate this issue. Zwitterionic polymers (ZPs) are a promising class of materials that reduce biofouling of implanted devices. A series of ZPs each containing tetherable epoxide functional groups was synthesised for application as a polymer shield for eventual application as implantable glucose biosensors. The polymer shields were initially tested for the ability to resist fibrinogen adsorption and fibroblast adhesion. All synthesised ZPs showed comparable behaviour to a commercial Lipidure ZP in resisting fibrinogen adsorption. Nafion, a common anionic shield used against electrochemical interferents, showed higher protein adsorption and comparable cell adhesion resistance as uncoated control surfaces. However, a poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate) (MPC)-type ZP showed similar behaviour to Lipidure, with approximately 50% reduced fibrinogen adsorption and 80% decrease in fibroblast adhesion compared to uncoated controls. An MPC-coated amperometric glucose biosensor showed comparable current density and a 1.5-fold increase in sensitivity over an uncoated control biosensor, whereas all other polymer shields tested, including Lipidure, Nafion and a poly(ethyleneglycol) polymer, resulted in lower sensitivity and current density. Collectively, these characteristics make MPC-polymer shield coatings an appealing possibility for use in implantable glucose sensors and other implanted devices with the aim of reducing FBR while maintaining sensor performance.

4.
Bioelectrochemistry ; 149: 108314, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36335789

RESUMEN

A new redox polymer/bilirubin oxidase (BOD)-based gas diffusion electrode was designed to be implemented as the non-current and non-stability limiting biocathode in a glucose/O2 biofuel cell that acts as a self-powered glucose biosensor. For the proof-of-concept, a bioanode comprising the Os-complex modified redox polymer P(VI-co-AA)-[Os(bpy)2Cl]Cl and FAD-dependent glucose dehydrogenase to oxidize the analyte was used. In order to develop an optimal O2-reducing biocathode for the biofuel cell Mv-BOD as well as Bp-BOD and Mo-BOD have been tested in gas diffusion electrodes in direct electron transfer as well as in mediated electron transfer immobilized in the Os-complex modified redox polymer P(VI-co-AA)-[Os(diCl-bpy)2]Cl2. The resulting biofuel cell exhibits a glucose-dependent current and power output in the concentration region between 1 and 10 mM. To create a more realistic test environment, the performance and long-term stability of the biofuel cell-based self-powered glucose biosensor has been investigated in a flow-through cell design.


Asunto(s)
Fuentes de Energía Bioeléctrica , Técnicas Biosensibles , Oxidorreductasas actuantes sobre Donantes de Grupo CH-CH , Bilirrubina , Electrodos , Enzimas Inmovilizadas/metabolismo , Glucosa , Glucosa 1-Deshidrogenasa/metabolismo , Oxidación-Reducción , Oxidorreductasas actuantes sobre Donantes de Grupo CH-CH/metabolismo , Polímeros , Gases
5.
ACS Appl Mater Interfaces ; 14(41): 46421-46426, 2022 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-36194638

RESUMEN

The development of electrodes for efficient CO2 reduction while forming valuable compounds is critical. The use of enzymes as catalysts provides the advantage of high catalytic activity in combination with highly selective transformations. We describe the electrical wiring of a carbon monoxide dehydrogenase II from Carboxydothermus hydrogenoformans (ChCODH II) using a cobaltocene-based low-potential redox polymer for the selective reduction of CO2 to CO over gas diffusion electrodes. High catalytic current densities of up to -5.5 mA cm-2 are achieved, exceeding the performance of previously reported bioelectrodes for CO2 reduction based on either carbon monoxide dehydrogenases or formate dehydrogenases. The proposed bioelectrode reveals considerable stability with a half-life of more than 20 h of continuous operation. Product quantification using gas chromatography confirmed the selective transformation of CO2 into CO without any parasitic co-reactions at the applied potentials.


Asunto(s)
Monóxido de Carbono , Formiato Deshidrogenasas , Formiato Deshidrogenasas/química , Monóxido de Carbono/química , Dióxido de Carbono/química , Polímeros , Instalación Eléctrica , Electrodos , Oxidación-Reducción
6.
Angew Chem Int Ed Engl ; 61(52): e202211559, 2022 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-36253337

RESUMEN

Despite the success of continuous glucose measuring systems operating through the skin for about 14 days, long-term implantable biosensors are facing challenges caused by the foreign-body reaction. We present a conceptually new strategy using catalytic enzyme-based biosensors based on a measuring sequence leading to minimum disturbance of the substrate equilibrium concentration by controlling the sensor between "on" and "off" state combined with short potentiometric data acquisition. It is required that the enzyme activity can be completely switched off and no parasitic side reactions allow substrate turnover. This is achieved by using an O2 -independent FAD-dependent glucose dehydrogenase embedded within a crosslinked redox polymer. A short measuring interval allows the glucose concentration equilibrium to be restored quickly which enables the biosensor to operate under quasi-equilibrium conditions.


Asunto(s)
Técnicas Biosensibles , Glucosa 1-Deshidrogenasa , Glucosa , Catálisis , Difusión
7.
Chemistry ; 28(30): e202201306, 2022 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-35532196

RESUMEN

Invited for the cover of this issue are Felipe Conzuelo, Wolfgang Schuhmann, and co-workers at the Ruhr University Bochum. The image depicts the electrochemical conversion of glycerol and 5-(hydroxymethyl)furfural with an electrode made up of galactose oxidase electrically wired with a redox polymer. Read the full text of the article at 10.1002/chem.202200868.


Asunto(s)
Electrones , Galactosa Oxidasa , Biotecnología , Humanos
8.
Bioelectrochemistry ; 146: 108128, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35429916

RESUMEN

Green microalgae are gaining attention in the renewable energy field due to their ability to convert light into energy in biophotovoltaic (BPV) cells. The poor exogenous electron transfer kinetics of such microorganisms requires the use of redox mediators to improve the performance of related biodevices. Redox polymers are advantageous in the development of subcellular-based BPV devices by providing an improved electron transfer while simultaneously serving as immobilization matrix. However, these surface-confined redox mediators have been rarely used in microorganism-based BPVs. Since electron transfer relies on the proximity between cells and the redox centres at the polymer matrix, the development of molecularly tailored surfaces is of great significance to fabricate more efficient BPV cells. We propose a bioanode integrating Chlorella vulgaris embedded in an Os complex-modified redox polymer. Chlorella vulgaris cells are functionalized with 3-aminophenylboronic acid that exhibits high affinity to saccharides in the cell wall as a basis for an improved integration with the redox polymer. Maximum photocurrents of (5 ± 1) µA cm-2 are achieved. The developed bioanode is further coupled to a bilirubin oxidase-based biocathode for a proof-of-concept BPV cell. The obtained results encourage the optimization of electron-transfer pathways toward the development of advanced microalgae-based biophotovoltaic devices.


Asunto(s)
Chlorella vulgaris , Microalgas , Ácidos Borónicos , Chlorella vulgaris/metabolismo , Oxidación-Reducción , Polímeros/metabolismo
9.
Chemistry ; 28(30): e202200868, 2022 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-35338670

RESUMEN

The use of enzymes as catalysts in chemical synthesis offers advantages in terms of clean and highly selective transformations. Galactose oxidase (GalOx) is a remarkable enzyme with several applications in industrial conversions as it catalyzes the oxidation of primary alcohols. We have investigated the wiring of GalOx with a redox polymer; this enables mediated electron transfer with the electrode surface for its potential application in biotechnological conversions. As a result of electrochemical regeneration of the catalytic center, the formation of harmful H2 O2 is minimized during enzymatic catalysis. The introduced bioelectrode was applied to the conversion of bio-renewable platform materials, with glycerol as model substrate. The biocatalytic transformations of glycerol and 5-hydroxymethylfurfural (HMF) were investigated in a circular flow-through setup to assess the possibility of substrate over-oxidation, which is observed for glycerol oxidation but not during HMF conversion.


Asunto(s)
Galactosa Oxidasa , Glicerol , Electrodos , Transporte de Electrón , Electrones , Enzimas Inmovilizadas , Galactosa Oxidasa/metabolismo , Oxidación-Reducción
10.
Nat Commun ; 13(1): 1129, 2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35236840

RESUMEN

Electrocatalytic recycling of waste nitrate (NO3-) to valuable ammonia (NH3) at ambient conditions is a green and appealing alternative to the Haber-Bosch process. However, the reaction requires multi-step electron and proton transfer, making it a grand challenge to drive high-rate NH3 synthesis in an energy-efficient way. Herein, we present a design concept of tandem catalysts, which involves coupling intermediate phases of different transition metals, existing at low applied overpotentials, as cooperative active sites that enable cascade NO3--to-NH3 conversion, in turn avoiding the generally encountered scaling relations. We implement the concept by electrochemical transformation of Cu-Co binary sulfides into potential-dependent core-shell Cu/CuOx and Co/CoO phases. Electrochemical evaluation, kinetic studies, and in-situ Raman spectra reveal that the inner Cu/CuOx phases preferentially catalyze NO3- reduction to NO2-, which is rapidly reduced to NH3 at the nearby Co/CoO shell. This unique tandem catalyst system leads to a NO3--to-NH3 Faradaic efficiency of 93.3 ± 2.1% in a wide range of NO3- concentrations at pH 13, a high NH3 yield rate of 1.17 mmol cm-2 h-1 in 0.1 M NO3- at -0.175 V vs. RHE, and a half-cell energy efficiency of ~36%, surpassing most previous reports.

11.
Org Biomol Chem ; 16(28): 5094-5096, 2018 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-29971288

RESUMEN

Fragmentation of electrochemically generated oxonium ions can be exploited to form carbenium ions at a low oxidation potential in the presence of a nucleophile. The application of this concept is demonstrated for the allylation of carbenium ions generated by the anodic oxidation of stannylmethylethers.

12.
Beilstein J Org Chem ; 11: 2166-70, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26664638

RESUMEN

Stable heterocyclic hydroperoxide can be easily prepared as a product of fast oxidation of a 1,2,3,4-tetrahydropyridine by (3)O2 if the solution is exposed to sunlight. The driving force for the photoinduced electron transfer is calculated from electrochemical and spectroscopic data. The outcome of the reaction depends on the light intensity and the concentration of O2. In the solid state the heterocyclic hydroperoxide is stable; in solution it is involved in further reactions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...